<p class="MsoBodyText"><span lang="EN-GB">This method gives a standardized procedure for the conditioning operation when selecting a conditioning product at laboratory scale and also for the production of flocculated thickened sludge for subsequent dewatering tests.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">This document provides a method for laboratory chemical conditioning of sludge.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">The method applies to sludges and suspensions from:</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">storm water handling;</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">urban wastewater collecting systems;</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">urban wastewater treatment plants;</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">industrial wastewater that has been treated similarly to urban wastewater;</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">water supply plants.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">This document is applicable to all sludge that can have similar environmental or health impacts, or both, with exclusion of hazardous sludge from industry and dredged sludge.</span></p>
Reģistrācijas numurs (WIID)
85951
Darbības sfēra
<p class="MsoBodyText"><span lang="EN-GB">This method gives a standardized procedure for the conditioning operation when selecting a conditioning product at laboratory scale and also for the production of flocculated thickened sludge for subsequent dewatering tests.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">This document provides a method for laboratory chemical conditioning of sludge.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">The method applies to sludges and suspensions from:</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">storm water handling;</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">urban wastewater collecting systems;</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">urban wastewater treatment plants;</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">industrial wastewater that has been treated similarly to urban wastewater;</span></p>
<p class="ListContinue1" style="mso-list: l0 level1 lfo1;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">—<span style="font: 7.0pt 'Times New Roman';"> </span></span></span><!--[endif]--><span lang="EN-GB">water supply plants.</span></p>
<p class="MsoBodyText"><span lang="EN-GB">This document is applicable to all sludge that can have similar environmental or health impacts, or both, with exclusion of hazardous sludge from industry and dredged sludge.</span></p>